How to use T8200Pro-G to find defect of a RFID card?

One of our customer purchase a batch of 30x50mm dual-frequency epoxy card with Mifare Plus X4K (HF) and TK4100 (LF). The cards had passed the test during fabrication. Resonant frequency test is normal, customer requirement 14.0±0.5MHz.

Reading and writing function test is normal, both universal card readers and mobile phones can read and write, including UID.

How to use T8200Pro-G to find defect of a RFID card?

After receiving the cards, the customer found that the card could not be issued normally.
The customer wanted us to find the cause, but the reader for the project is inconvenient to provide.

Can the professional testing tool T8200Pro-G findout the problem?

It’s known to all that there are three major factors to judge a RFID product. Frequency, Q value and attenuation.

Using T8200Pro-G can test these three factors simultaneously.

Testing result

Frequency13.734 MHzNormal(green)
Attenuation-1.329 dBNormal(green)
Q value31.182Normal(green)
Communication test resultFAIL(red)
14443A UIDN/A(gray)

How to use T8200Pro-G to find defect of a RFID card?How to use T8200Pro-G to find defect of a RFID card?

Testing board: 40mmx40mm

Frequency123.423 KHzNormal(green)
Attenuation-1.361 dBNormal(green)
Q value9.558Normal(green)

How to use T8200Pro-G to find defect of a RFID card?How to use T8200Pro-G to find defect of a RFID card?

Testing board: LF testing board

Problem analysis and solution

HF Inlay performance problems

The frequency, Q value and attenuation tests can be displayed normally, but the dB value is found to be too small and the communication test fails. Based on experience and reasoning, it may be related to the size and design of the antenna.

New antenna design: Enlarge the size of the HF antenna.

How to use T8200Pro-G to find defect of a RFID card?

– Original antenna:
HF and LF are arranged side by side with circular antenna.

– New antenna:
HF is replaced by a larger square antenna and place the LF antenna inside the HF antenna.

After improvement

Testing result

Frequency14.174 MHzNormal(green)
Attenuation-7.499 dBNormal(green)
Q value36.308Normal(green)
Communication test resultPASS(green)
14443A UID0408xxxxxxxx(7bit)

How to use T8200Pro-G to find defect of a RFID card?

Frequency122.523 KHzNormal(green)
Attenuation-1.741 dBNormal(green)
Q value9.600Normal(green)

How to use T8200Pro-G to find defect of a RFID card?

Customer feedback after receiving improvement:

Conclusion

Only measured frequency and general read and write for non – standard small card or micro tag is not enough!

Except frequency, Q value and attenuation are also the key parameters to measure the performance of label!

Designing antenna or verifying label performance must use professional testing tools!